Technichal data |
DBA-250D |
Output power |
375W/250 W (program/RMS) |
Input sensitivity |
1V, 10 kohms, balanced |
Output voltage |
50 V or 100 V |
Frequency response |
70 ~ 20.000 Hz (better than -3 dB) |
Signal-to-noise-ratio |
better than 91 dB |
THD at 1 kHz |
better than 0,29% |
External voltage distance |
85 dB 1kHz |
Power consumption |
Sine signal-380 W, no-load-18 W, standby 7W |
Current consumption (230 V AC) |
Sine signal-1,7 A, active 0 W Out-0,09 A, standby-0,034 A |
Current consumption (24 V DC) |
Sinussignal-14 A, active 0 W Out-0,3 A, standby-0,06 A |
AC power supply |
230 V, 50 – 60 Hz |
DC power supply |
24 V (emergency power supply) |
Dimensions (W x H x D in mm) |
483 x 88 x 256; 2 RU |
Weight |
Technichal data |
DBA-500D |
Output power |
750W/500 W (program/RMS) or 2x375W/2x250 W (program/RMS) |
Input sensitivity |
1V, 10 kohms, balanced |
Output voltage |
50 V or 100 V |
Frequency response |
70 ~ 20.000 Hz (better than -3 dB) |
Signal-to-noise-ratio |
better than 91 dB |
THD at 1 kHz |
better than 0,2% |
External voltage distance |
85 dB 1kHz |
Power consumption |
Sine signal-770 W, no-load-35 W, standby 9W |
Current consumption (230 V AC) |
Sine signal-4 A, active 0 W Out-0,15 A, standby-0,048 A |
Current consumption (24 V DC) |
Sine signal-27 A, active 0 W Out-0,5 A, standby-0,12 A |
AC power supply |
230 V, 50 – 60 Hz |
DC power supply |
24 V (emergency power supply) |
Dimensions (W x H x D in mm) |
483 x 88 x 256; 2 RU |
Weight |
16,2 kg |